The first letters tell you how the unit is fixed. SY 1.1/2 TF is a pillow block and FY 1.1/2 TF is a square flange, both for the same shaft. In these series the number is the shaft diameter: with a point and a fraction when it is in inches, as in both examples, and a whole number when it is in millimetres, as in SY 25 TF. The final block of letters refers to the insert fitted in the unit and must be copied.
In UCP 205 and UCF 205 the logic changes: P and F are again pillow block and flange, but 205 is a series size, not a direct shaft dimension. That is why comparing numbers between one family and another is not enough. If the part number also carries a slash and letters at the end, it is a variant of the same unit and is part of the reference.
In the MR catalogue, SKF Y-bearing units are grouped by housing: pillow blocks, SY and its variants SYJ, SYR, SYNT, SYF and SYWK; flanged units, FY, FYJ, FYC and FYTB; and TU take-up units.