Skip to content
Monday through Friday, 8:00 to 17:30 (continuous)
All products
Circular taconite seal with flange and mounting holes, for bearing housing · SKF TER 524/110/C-09-065
Housing covers and accessories SKF TER 524/110/C-09-065

Product page

Housing covers and accessories SKF TER 524/110/C-09-065

Manufacturer Part Number
TER 524/110/C-09-065
Brand
SKFOfficial brand
Category
Bearing housings
Subcategory
Housing covers and accessories

Other brands in this family

Ask us about alternatives. Equivalence is verified for each reference and application.

SKF

We respond promptly.

Request your quote via WhatsApp or email, with the quantity and time frame you need.

Can't find the exact model? Write to us with the part number or model you're looking for: we'll find it and quote it, even if it's not listed in the catalog.

Ask via WhatsAppAsk via email

Description

SKF TER 524/110/C-09-065 is a housing covers and accessories reference, within Bearing housings. Request a quote for TER 524/110/C-09-065 via WhatsApp or email with the quantity you need; we respond promptly with lead time and equivalents.

TER line end covers are closure components for split or solid bearing housings. Their function is to cover the housing, retain lubricant and protect the bearing from dust, moisture and particles typical of industrial environments. They are mounted on the housing and, depending on the model, may include a labyrinth, radial shaft seal or gasket. At MR Accesorios Industriales we supply the SKF line and help you identify the exact end cover from the code marked on the part or from the equipment drawing.

The designation of these end covers combines letters and numbers that refer to the housing and the sealing variant. In the example TER 524/110/C-09-065, the numeric block identifies the housing size it corresponds to, while the hyphen-separated suffixes indicate the type of seal, material or finish. Since the nomenclature varies by series, the safest way to order it is to copy the full code exactly as it appears on the part or in the machine manual.

These end covers are used in equipment in aggressive environments: conveyor belts, mills, mixers, pumps, fans and drives in food, chemical, cement and aggregate processing plants. In Argentina we see them in sugar mills, cold storage plants, animal feed plants and quarries, where dust or frequent washing demands a reliable seal. They are also replaced during scheduled maintenance of SKF housings already installed on equipment.

To choose the correct end cover, take into account the housing type, shaft diameter, sealing system and working environment. Labyrinth versions are suitable for high speeds and heavy contamination; those with a contact seal seal better against liquids, although they generate somewhat more friction. During installation, check alignment with the housing, do not strike the end cover and verify that the gasket or seal seats without deforming. Proper bearing lubrication complements the sealing.

End covers from different brands are not always interchangeable with each other, even if the housing has similar dimensions. Differences appear in the fitting diameter, height, mounting type and sealing system. That is why it is advisable to compare drawings or measure the part before replacing one end cover with another. If you do not have the code, send us the main measurements and a photo of the housing: at MR Accesorios Industriales we guide you to identify the compatible reference.

If you need a quote for a TER end cover, write to us on WhatsApp with the full code, the housing brand and the quantity. The more data you give us, the faster we can confirm the variant and send you the quote. We handle technical maintenance and replacement inquiries for plants throughout Argentina.

This description provides guidance on the product type. Check the configuration and dimensions of this reference.

Dimensions

Dimensions and tolerances: Send us the part number via WhatsApp and we'll confirm dimensions, sealing, and internal clearance against the manufacturer's data sheet.

Frequently Asked Questions

How do I identify the TER end cover I need?
Copy the full code marked on the end cover or on the housing, for example TER 524/110/C-09-065. If you do not have it, send us the housing measurements, shaft diameter and a photo. With that data we can locate the compatible reference.
Do TER end covers fit housings from other brands?
Not always. Even if the housing has similar dimensions, the fit, height and type of seal change. Compare drawings or measure the part before replacing. If in doubt, consult us with the measurements and we will guide you.
What is the difference between a labyrinth end cover and one with a seal?
The labyrinth one seals without contact and better withstands high speeds with dust. The one with a seal has a lip that rubs against the shaft and better blocks the entry of liquids, although it generates more friction. The choice depends on the environment and speed.
Request a quote on WhatsApp