Skip to content
Monday through Friday, 8:00 to 17:30 (continuous)
All products
NTN 4-bolt flange mounted bearing · NTN UCF205-014D1
Flange bearing 4 holes NTN UCF205-014D1

Product page

Flange bearing 4 holes NTN UCF205-014D1

Manufacturer Part Number
UCF205-014D1
Brand
NTNOfficial distributor
Category
Bearing housings
Subcategory
Y-bearing unit
Series
UCF2

Other brands in this category

Ask us about alternatives. Equivalence is verified for each reference and application.

NTN

We respond promptly.

Request your quote via WhatsApp or email, with the quantity and time frame you need.

Can't find the exact model? Write to us with the part number or model you're looking for: we'll find it and quote it, even if it's not listed in the catalog.

Ask via WhatsAppAsk via email

Description

NTN UCF205-014D1 is a flange bearing 4 holes reference, within Bearing housings. Request a quote for UCF205-014D1 via WhatsApp or email with the quantity you need; we respond promptly with lead time and equivalents.

The NTN Y-bearing insert flange unit is a 4-bolt flange mounted assembly that combines a cast iron housing with a self-aligning insert bearing. It is used to support rotating shafts in equipment where rigid fastening to a flat surface is required, such as conveying machines, agitators or transmission systems. MR Accesorios Industriales sells this line with the technical assistance you need to choose the correct part number for your application.

The UCF designation identifies a 4-bolt flange housing with insert bearing. The numbers that follow indicate the size: UCF2 groups the metric shaft mountings of series 2, and UCF3 those of series 3, with higher capacity. The D1 suffix indicates a construction variant of the insert, and when a hyphen with three digits appears — for example UCF201-008D1 or UCF204-012D1 — those digits correspond to the inch measurement of the shaft. Thus, UCF201D1 and UCF201-008D1 share the same housing but a different shaft diameter. With the complete part number we quote exactly what you need.

These housings are seen in belt conveyors, bucket elevators, mixers, centrifugal pumps, fans and packaging lines. In the Argentine market they appear both in food plants and in chemical plants, cement plants and metalworking workshops. The 4-bolt flange allows them to be mounted on sheet metal or angle iron structures, and the self-aligning insert absorbs small shaft misalignments. MR Accesorios Industriales sells them for replacement and for new projects, backed by a company with more than 80 years in the industry.

To choose well, first look at the shaft diameter and the type of load: radial, axial or combined. Check that the flange has a bolt hole spacing compatible with your structure. The insert sealing defines whether it is suitable for a dusty or humid environment: some have a single lip seal or additional protection. Lubrication comes from the factory, but in service it is advisable to check the condition of the grease and the alignment of the flange before tightening the bolts. A stress-free mounting prevents deformation and extends bearing life.

If you are replacing an existing unit, the housing part number and the shaft diameter are the key data. UCF series from different brands are usually interchangeable in dimensions and holes, but the housing material or the type of sealing may vary. When the original part number is not available, it can be cross-referenced by dimensions: shaft diameter, bolt hole spacing and overall height. Write to us on WhatsApp with those data and we will indicate the compatible alternative or quote the exact part number shown on your equipment.

Whether you need a UCF201D1, a UCF204-012D1 or any other reference in the line, at MR Accesorios Industriales we will quote it for you shortly. Send us the complete part number or the measurements of your shaft and flange, and we will reply with the option that best suits your application.

This description provides guidance on the product type. Check the configuration and dimensions of this reference.

Dimensions

Eje o agujero
7/8 in

Frequently Asked Questions

What does the D1 suffix mean in a UCF housing?
The D1 suffix identifies a construction variant of the insert bearing, generally associated with a specific type of sealing or tolerance. It does not change the flange dimensions or the shaft diameter. To know exactly which version you need, send us the complete part number and we will quote it.
How do I choose between a UCF2 and a UCF3?
The UCF2 series covers smaller shaft diameters and the UCF3 larger shafts, with higher load capacity. The choice depends on the shaft diameter and the radial and axial loads of your equipment. If you give us those measurements, we will recommend the right series.
Are NTN UCF housings interchangeable with other brands?
In general, UCF series from different brands share flange dimensions and shaft diameters, so they are usually interchangeable. The housing material or the sealing may vary. If you send us the part number of the original brand, we will quote the NTN equivalent or the option that best suits you.
Request a quote on WhatsApp