Blog
SNR dimensions: how to identify the code from the part and what data to send for a quote
Identifying an SNR bearing by the dimensions marked on it is easier than it seems. We show you what to look at on the part, how to read the code and what information to send us for a quote without hassle.
Technical team at MR Accesorios Industriales · Updated on November 19, 2026

How to read the code marked on an SNR bearing
When you have an SNR bearing in your hand, the first thing to look at is the code marked on the outer ring or on the seal. That code is the key to knowing exactly which part it is, without relying on memory or an old catalog. On Y insert bearings, the code is usually clearly visible and combines letters and numbers, such as UC204G2. If the part is very worn or dirty, clean the area with a cloth and use raking light so the characters stand out.
The code is not a unique serial number: it is the model designation, and it is repeated on all identical parts. So if you have several bearings on the same equipment, reading one well is enough. In the case of Y-bearings, the UC series is very common and is used in pillow block housings, take-up units and agricultural applications. The number that follows indicates the bore diameter in millimeters, but it is not always direct: for example, UC204 corresponds to 20 mm, UC205 to 25 mm and UC206 to 30 mm.
If the code is partially erased, you can measure the inner diameter, outer diameter and width with a caliper. Those three measurements, together with a photo of the part, allow us to identify the model quite accurately. It also helps to check the type of shaft fixing: SNR Y-bearings usually have set screws or an eccentric collar. With that data, we quote you the exact replacement or the equivalent alternative.
SNR Y-bearings: most used dimensions and series
SNR Y-bearings are recognized by their spherical outer ring and their extended inner ring, which can be fixed to the shaft with screws or with an eccentric collar. They are the standard option for pillow block housings, flanges and take-up units in agricultural machinery, conveyors and processing equipment. The UC series is the most widespread, and codes such as UC204G2, UC205G2 or UC206G2 appear in a huge number of applications.
To identify the bearing, in addition to the code, it is advisable to measure the bore diameter accurately. In the UC series, the number after the letters follows a rule: the last two digits multiplied by 5 give the diameter in millimeters for the smaller sizes. Thus, UC204 is 20 mm, UC205 is 25 mm and UC206 is 30 mm. Still, it is always better to confirm with the actual measurement.
A common mistake is to order the bearing only by shaft size, without checking the type of seal or fixing. If the bearing works in an environment with dust, water or vibration, it is worth clarifying when ordering. Send us the complete code and a photo of the old bearing to avoid confusion.
SNR Y housings with insert bearing: how they are identified
SNR Y housings with insert bearing combine a cast iron or sheet steel housing with a Y-bearing already mounted. They are very practical because they are installed as a complete unit, without the need to assemble the bearing inside the housing. The codes of these assemblies start with UCP, UCF or UCT, depending on the type of housing: pillow block, flange or take-up. For example, UCP210 is a pillow block housing with insert bearing for a 50 mm shaft.
To identify an SNR Y housing, look at the plate or the housing body, where the complete code is usually marked. If the housing is painted or very rusty, you can gently scrape the marked area. It is also useful to measure the distance between the fixing holes and the diameter of the bearing bore. With that data and a photo, we can confirm the exact model, such as UCP211 or UCP212, which correspond to 55 mm and 60 mm shafts respectively.
When quoting a Y housing, the code of the internal bearing is not enough: the housing also has its own designation, and sometimes they are sold separately. If the bearing is damaged but the housing is sound, you can order only the insert; if the base is broken, it is better to replace the complete assembly. In any case, send the code you see on both parts and the measurements of the fixing holes to ensure compatibility.
What data to send to quote an SNR bearing or housing
To quote quickly and without back-and-forth, the ideal is for you to send us the complete code you read on the part, for example UC204G2 or UCP210. If the code cannot be read, measure with a caliper the inner diameter, outer diameter and width of the bearing, or the center distance between holes in the case of a housing. Those numbers allow us to search the dimension tables and give you an accurate answer.
In addition to the measurements, a photo of the part helps a lot, especially if it has a particular seal, cap or fixing. In the photo you can see whether the bearing has set screws, an eccentric collar or any special treatment. It is also useful to know which machine it works on and under what conditions: temperature, presence of water or dust, and approximate speed. That information guides us to offer you the correct replacement.
Don't worry if you don't have all the data: with the code or the main measurements we can already start the search. We are an official SNR distributor, so we work with genuine product and can advise you on the best option for your application. Write to us by WhatsApp or email with the information you have and we will reply promptly.
Common mistakes when ordering Y-bearings and SNR housings
One of the most frequent mistakes is ordering the bearing only by shaft size, without considering the type of housing or fixing. For example, a 25 mm shaft can use a UC205, but also a bearing from another series with a different width or seal. If the complete code is not clarified, you may receive a part that does not fit into the housing or does not fix well to the shaft.
Another mistake is confusing the bearing code with the housing code. In a UCP210 assembly, the internal bearing is a UC210, but if you ask only for “the UCP210 housing” it can be interpreted as the housing alone. It is always advisable to clarify whether you need the complete assembly, only the bearing or only the housing. That avoids delays and returns.
It is also common not to check the condition of the seal or lubrication when replacing. When mounting, verify that the seal is intact and that the bearing turns smoothly. If you have doubts about mounting, ask us: we guide you through the basic steps for a correct installation.
How to measure an SNR bearing without the code
If the code is illegible, you can identify the bearing by its three main measurements: inner diameter (bore), outer diameter and width. Use a caliper or micrometer, and measure in millimeters with the greatest possible precision. For example, a Y-bearing with a 20 mm bore, 47 mm outer diameter and 31 mm width corresponds to a UC204. Those measurements, together with a photo, are enough for us to locate the model.
To measure the inner diameter on a Y-bearing, place the caliper on the edge of the bore and read the measurement. If the bearing has an eccentric collar or screws, do not include them in the measurement. The outer diameter is measured on the outer ring, at the widest part. The width is taken from face to face of the bearing, not counting protruding seals. Write down the three measurements and any visible detail.
In the case of a Y housing, measure the distance between the centers of the fixing holes and the diameter of the bearing bore. It also helps to measure the total height of the housing and the width of the base. With that data, we can search the SNR tables and confirm whether it is a UCP, UCF or UCT. Send us the measurements by WhatsApp or email and we will quote you right away.
Why it is worth identifying the SNR code well before buying
Correctly identifying the SNR code ensures you receive the exact part for your machine, without adaptations or surprises. A Y-bearing or an insert housing that does not match in dimensions or fixing can generate vibrations and unplanned stoppages.
In addition, with the correct code you can compare options within the same brand: for example, between a UC205G2 and other variants of the same size, we can advise you on which is best for your application. As an official SNR distributor, we can indicate the best alternative according to use.
Finally, sending the correct code or measurements speeds up the quote and avoids order errors. You don't need to be a bearing expert: with a photo and a couple of measurements, we do the rest. Write to us today by WhatsApp or email with the data of your SNR part and we will reply with the right proposal.
Frequently asked questions
How do I identify the code of an SNR bearing?
Look for the code marked on the outer ring or on the seal. It usually combines letters and numbers, such as UC204G2. If it is blurry, clean the area and use raking light. If it cannot be read, measure inner diameter, outer diameter and width with a caliper and send us a photo.
What does the number in an SNR UC bearing mean?
In the UC series, the last two digits multiplied by 5 give the bore diameter in millimeters for the most common sizes. For example, UC204 is 20 mm, UC205 is 25 mm and UC206 is 30 mm.
How do I identify an SNR Y housing?
Look at the code marked on the housing, such as UCP210. If it is not visible, measure the distance between the fixing holes and the diameter of the bearing bore. With that data and a photo we can confirm the model.
What data do I need to quote an SNR bearing?
Send us the complete code of the part, or the main measurements (inner diameter, outer diameter and width) and a photo. It also helps to know which machine it works on and the operating conditions.
Can I order only the Y-bearing without the housing?
Yes, SNR Y-bearings are sold separately from the housing. Just clarify it when quoting: whether you need the insert, the housing or the complete assembly, so we can offer you the right thing.
Products with photos in the catalogue
Keep reading
- SNR in Argentina: Complete Product Guide and How to Get a Quote
Discover the SNR product lines available in Argentina, their applications, and how to get a quote by code with an official distributor.
- SNR: How to Read Bearing Codes and Designations
Practical guide to understanding SNR bearing nomenclature: what numbers, prefixes, and suffixes mean, with real examples. Learn to identify the correct bearing for your application.
- SNR Bearings: Applications, Selection and Maintenance for Lasting Performance
SNR bearings stand out in demanding industrial applications. Learn where they are used, how to choose the right model, and best practices for mounting and maintenance.
Continue here
Need a SNR quote?
Send us the SNR part number, the size or a photo of the part and we will get back to you with a quote.

